Guangzhou Jin Lun Electric Equipment Co.,Ltd

19 Years Professional Heat Pump Manufacturer!

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHydronic Heat Pump

MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump

MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump

  • MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump
  • MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump
  • MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump
  • MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump
MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump
Product Details:
Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CE ISO CCC UKAS,ROHS
Model Number: MD60D
Payment & Shipping Terms:
Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, L/C WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Materail: Coated Matel Contactor: Fuji Brand
Copper Thick: 1 Mm Compressor: With Oil Heater
Display: LCD Finger Touch Control: Wifi Function Support
Certification:: CE, CCC Installation:: Freestanding
Noise:: Low Noise
High Light:

meeting heat pump

,

american standard heat pump

MD60D Top blowing 21KW Floor Heating Air Source Low Temp Heat Pump

 

Technology Specification

 

 

Features&Benefits :

 


  Easy installation with different water tanks

 

  High efficiency with good performance

 

  Famous brand  copeland compressor with R410a

 

 Enlarged heat exchangers, high COP

 

  Whisper quiet fan

 

 Intelligent controller

 

  Reverse cycle defrost with 4-way valve

 

  Hydrophilic fin coil coating

 

 Operation protection included

 

 

100% factory tested

 

 

 

Household air source heat pump (Mono-block type) has following important features:

 

1. Working air temperature range:-20 to 45

 

2. Max outlet water temperature: 60

 

3. Circulating water pump inside( or outside heat pump)

 

4. Copeland  compressor

 

5. R417A/R407C/R404Arefrigerant

 

6. Air temperature too low protection

 

7. High efficiency shell and tube water heat exchanger

 

MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump 0

 

MD60D Top blowing 21KW Hydronic Heat Pump / Floor Heating Air Source Low Temp Heat Pump 1

 

 

Our Services

 

1. After installation, our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation during the guarantee period.

 

2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.

 

3. We accept OEM, ODM and customization.

 

4. 24*7 after sales service. You will get satisfied service.

 

5. We have More than 17years production and sales experience; Professional sales team.

 

 

Packaging & Shipment

1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

 

2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

 

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

 

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

 

5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

Delivery Time :15 work days after arrival of down payment

 

 

 

 

Air source heat pump parameter  tebles 

 

MODEL Unit MD60D
Rated heating capacity KW 21
Rated Cooling capacity   15
Hot water supply L/h 520
Average heating input power KW 5.68
Rated heating input current 12
Max outlet water temp 60
COP   4.2
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 210
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000
Water pressure down Kpa 48
Pipe size DN 25
Max flat spuare meter M2 175

 

 

Contact Details
Guangzhou Jin Lun Electric Equipment Co.,Ltd

Contact Person: Ms. Alinna

Tel: +86 13922152741

Fax: 86-20

Send your inquiry directly to us (0 / 3000)

Other Products